- Test Chambers
- Laboratory Equipmemts
- Sterilization Equipments
- Clean Room Equipments
- Lab Water Solutions
- Measuring Meter
Leaf Area Meter (Acm-52301-J)

Weiber leaf area meter is compact, accurate tabletop instrument to check area of leaf. The operation is very easy, even a layman can operate. This instrument can also be used to check area of non-transparent flat surface material like cloth/paper/plastics/leather etc. This instrument is based on photometric technology.
Technical Specifications:
- Measuring Area:set of circular mask plates.
- Light Source: Fluorescent light source.
- Detector:photo sensors with built in area.
- Accuracy: A + .3sqcm for checking small area. + 1 sq cm for checking larger area
- Power Requirement:230v, 50hz., one cvt more than 100 va capacity.
- Price: the cost of one single standard unit with all standard accessories.
Function:
Acm-52301-j leaf area meter can measure area of plant (alive or not alive), abnormity Firgure quickly, used in agriculture, forestry, weather.
2. Main technical sheet
To measure area of plant leaf (alive or not alive), abnormity firgure
Quickly, used in agriculture, forestry, weather.
Acm-52301-j micro electro
1. Measuring area
500a<500cm2 (three range) 0-500cm2 0-300cm2 0-150cm2
2. Error : not exceed + 3% of full scale
3. Display -lcd
4. Distinguish -1cm2 min
5. Accumulate memory- 65535cm2 max
6. Display memory.
7. Size: 500a: 420x 340x 110 (mm)
8. Measusre area:
Area cm2 ersorr cm2
0-150 + 5
0-300 + 9
0-500 + 15
9. Weight : 2.7kg
3. Frame
Measuring board zero adjust sketchy display battery board back button
Full scale choice memory button zero button measurement button memory display
(z) (m)
Power switch zero adjust inching press board
How to use:
A. Lamp-house and standard frame choice
Open the case, select the correct uniformity lamp-house (example the outside Dispersion lamp), require the illumination of the bright side is same (the illumination Min is zero), The max can clear the “lobat 1999” on the display, if can’t clear should weaken the Illumination)
B. Press the power switch
It display(the tolerant is 5000 standard board, unit is cm2 Memory is zero), press the zero button, the instrument display the stochastic number, Adjust the zero adjust screw, sketchy first then adjust the inching, let it disply 000, put The standard board on the measure board, if according to the error require, let the Object on the measuring board, cover the press board, them measure the area.
C. Standard board sum the result
If the oject area is bigger than the measure board, we can divide into small part, then Sum the result.
For example, the first area is 210cm2 , press the measure button (m) it display “lobat210” Press the memory button(m+), it display 11 character. Then press the zero button(z), it display The stochastic number, adjust the zero button (z), take the object on the measure board, for Example it display 198cm2 , press the measure button(m), it display lobat198cm2 , press the Memory button(m+), then display 11 character, the result memories. If need measure and memory several time, only press the rm button, it can display the memory Button. If it not exceed 999, it will display directly, if exceed 999, it only display two character for Example lobat13, press the rm second time, display 084, so the memory is 13084. If the memory is over 65535, it display 88, it means the memory is overflow, it need press rm, Then can read the result, the result is before the last time measured. If need to measure continute, Should press rst button, clear the memory.
How to use the standard board?
- Acm-52301-j default is 500, without standard board, press the zero button,(z) adjust the sketchy
- First then adjust the inching screw, when it display 000 we could measure.
- Press full scale choice button it display 300, take the 300 standard board, then take the same
- Processing as above.
- Press full scale choice button for second time, it display 150, take the 150 standard Board.
- Press full scale choice button for third time, it display back to 500.
- Acm-52301-j default is 500, without standard board, press the zero button(z), adjust the sketchy
- First then adjust the inching zero adjust screw, when it display 000 we could measure.
- Press full scale choice button for second time, it display 150, take the 150 standard board.
- Press full scale choice button for third time, it display back to 300
- If need to change the standard, should press the rst button first, and the memory will be cleared.
Euphotic area measure
Not euphotic leaf we think the s1=s2 (s1 mean the measure result, s2 mean the real area) if the
Leaf euphotic is too much, s1 How to got rate of the euphotic? Take the standard board on the measure board, take something clearly cover the object, for Example, use the 150 standard board, with cover the clearly thing, the result is 144, if cover with Opacity thing the result is 150, so the rate of the euphotic isη = (s-s)/s * 100% Η -- -- mean the rate of the euphotic S---- mean measure area cover with the opacity thing. S ---- mean the real area S=s * (1+η) For example if measure the leaf s=98cm2 Η = (100-98)/98*100%=2.0408% S = 98*(1+20.408%)=99.99cm2 Actually the thick of the leaf not as same, so the euphotic rate is not same, we need to measure
The rate for every leaf.
Attention
- The instrument work condition in 0--400c
- With the uniformly lamp-house
- Work for one people one instrument
- Need to adjust the zero regularity
- Shutdown the power, if not use it
- It display 000 mean power off, need to change 2x 9v battery
- Repair reason repair
- Not display no battery change battery
- Can not adjust zero too dark take the bright lamp
- Too much error lamp house do not change the lamp house
- Uniformity or not or change the
- Steady going instrument position.
Other Product of Measuring Equipments