Test Chamber & Scientific Equipment Manufacturers

Air Cooled Chillers Manufacturers and Air Cooled Chillers India

  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Testimonials
  • Enquiry
  • Contact
  • Telephone: +91 11 47619688
  • Fax: +91 11 47619788
  • Email: info[@]acmasindia.com
  • Test Chambers
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Ovens
  • Bath & Chillers
  • Incubators
Product Range
  • Test Chamber
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Oven
  • Bath & Chillers
  • Incubators
Our Clients
  • Clients of ACMAS
World Wide Presence
  • Worldwide Presence of ACMAS
Achievements
  • Achievements of ACMAS
Resources
  • Resources
Weiber Advance Control Systems
  • Advance Control Systems
bath chillers
  1. Home
  2. Bath & Chiller
  3. Industrail Chiller
  4. Air Cooled Industrial Chillers
  • Air Cooled Industrial Chillers Manufacturers

AIR COOLED INDUSTRIAL CHILLERS

WEIBER industrial chillers (air cooled) is a refrigeration system used to cool a process fluid and dehumidifies air in industrial facilities. Air cooled chiller uses fans to dissipate the heat removed by the refrigeration system. The equipment works as an air conditioning system with the world's best standard A-type screw compressor and newly designed shell and tube heat exchanger that have powerful cooling ability, low noise, low vibration, high efficiency and high reliability. These are equipped where no source of liquid are available for cooling the condenser.


Air Cooled Chiller comes complete with PID microprocessor-controlled controller that utilizes fully proportional cooling and heating. The equipment offers low-stress refrigeration system, circulating pumps, R-134A CFC free refrigerant and fluid reservoir. WEIBER gives you an option to choose from the seven models as per the desired recirculating fluid and other technical parameters.We specialize in both standard as well as customized chillers to meet the demands in required areas.

  • STANDARDS COMPILED
  • SPECIAL FEATURES
  • CONSTRUCTION DETAILS
  • TECHNICAL MATRIX
  • APPLICATIONS
  • ARI 590
  • NFPA 70
  • NFPA 79
  • BS EN 1048:1999
  • BS EN 1048:2014
  • ASHRAE 90.1
  • Multi Channel Systems for multiple cooling loop applications
  • Precision temperature stability
  • Special fluid handling (materials, pumps, filtration)
  • Portable and reliable
  • Ergonomic designs
  • Microprocessor based controller (HMI+PLC based controller option)
  • CFC free refrigeration system
  • Hermetically sealed compressor
  • RS 232 interfacing for remote control and monitoring
  • Options for recirculating fluids (see the technical matrix of all models)
    • Water
    • Deionized Water
    • Deuterium Oxide / Methanol
    • Fluorinert FC-3283
    • Ethylene Glycol
  • Front to rear airflow
  • Audio visual alarms for malfunction
  • Castors for ease in mobility
  • Safety devices
  • suitable for use in both closed loop and ground loop water-source
  • equipped with rotary screw compression
  • equipped with includes particle filters, DI filters, water resistivity probes and rotary flow meters

    The heavy duty frame is constructed of welded steel tubing mounted on locking casters.

    HEATING

    Indirect heating system is provided in our chiller, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage. The temperature is evenly distributed throughout the chamber through natural water convection mechanism, ensuring a very good temperature sensitivity.

    COOLING UNIT

    An energy efficient cooling unit is installed in our chiller. We use ISI marked high end CFC free compressors of Kirloskar / Tecumseh make, conforming to latest international standards and guidelines.

    TEMPERATURE RANGE

    Temperature range of our chiller models vary for different models (see the technical matrix.) how ever we have the capacity to change the temperature specifications as per requirement

The below mentioned specifications are of our standard chillers. However we are fully capable to cater to the demand of any customized specification for any special application.

  • ACM-CHL-5201
    • Temperature Range +10°C to +20°C
      Number of Channels 1
      Cooling Capacity 586 Watts at +10°C
      Heating Capacity -
      Temperature Stability ± 0.4°C or better
      Fluid (HTF) Deuterium Oxide / Methanol
      Reservoir Volume 1 Gallon
      Pump: Flow at Pressure 1 GPM at 120 PSI
      Input Power 208/240VAC, 60Hz, 1ph, 20 Amp
      Configuration Indoor, Air cooled
      Recirculating Fluid Deuterium Oxide/Methanol 80/20 mix
      all materials compatible with DI water
      Recirculating Supply/Return Fittings 1/2" Stainless Steel FPT
      Condenser Cooling Air Flow 350 CFM front to rear
      Maximum Heat Rejection to Ambient 3,000 BTU/Hr
      Electrical Service 208/240 VAC, 60 Hz, single phase, 20 amp service
      Physical Parameters 45"H x 22.5"W x 30"D, 300 lbs dry weight
    • ACM-CHL-5202
      Temperature Range 0°C to +60°C
      Number of Channels 1
      Cooling Capacity 1.8 KW at +10°C (60Hz)
      1.5 KW at +10°C (50Hz)
      Heating Capacity 1.5 KW
      Temperature Stability ± 0.5°C or better
      Fluid (HTF) Fluorinert FC-3283
      Reservoir Volume 2.5 Gallon
      Pump: Flow at Pressure 2.5 GPM at 50 PSI
      Input Power 200/240VAC, 50/60Hz, 1ph, 25 Amp
      Configuration Indoor, Air cooled
      Recirculating Supply/Return Fittings 1/2" Stainless Steel FPT
      all materials compatible with DI water
      Condenser Air Flow 1,100 CFM Front-to-Rear
      Heat Rejection to Ambient 14,000 BTU/hr maximum
      Electrical Service 200/240 VAC, single phase,
      50/60 Hz, 25 amp service
      Physical Parameters 52" H x 24" W x 34" D
      550 pounds dry weight
      Refrigerant HFC Type R-507
      Compressor 1.5 Hp Hermetically-sealed
      Pump 1.5 Hp Magnetically-coupled Turbine powered by a variable frequency drive (VFD) to provide adjustable output flow and pressure
      Safety Interlocks Reservoir low level and empty fl oat switches, refrigerant high and low pressure switches, fluidflowmeter and pressure gauge, over-temp and over-pressure switches.
      Controller Microprocessor based PID controller
      Interface RS-232 for Remote Control and Monitoring
    • ACM-CHL-5203
    • Temperature Range 0°C to +60°C
      Number of Channels 1
      Cooling Capacity 3.6 KW at +10°C (60Hz)
      3.0 KW at +10°C (50Hz)
      Heating Capacity 3.0 KW
      Temperature Stability ± 0.5°C or better
      Fluid (HTF) Fluorinert FC-3283
      Reservoir Volume 5 Gallons
      Pump: Flow at Pressure 4 GPM at 50 PSI
      Input Power 200/240VAC, 50/60Hz, 1ph, 40 Amp
      Configuration Indoor, Air cooled
    • ACM-CHL-5204
    • Temperature Range +15°C to +40°C
      Number of Channels 1
      Cooling Capacity 22 KW +21°C fluid
      Heating Capacity 10 KW
      Temperature Stability ± 0.5°C or better
      Fluid (HTF) Water
      Reservoir Volume 10 Gallons
      Pump: Flow at Pressure 10 GPM at 25 PSI
      Input Power 440/480VAC, 60 Hz, 3ph, 50 amp
      Configuration Indoor, Air cooled
      Recirculating Supply/ Return Fittings 3/4" Stainless Steel FPT
      Condenser Air Flow 7,800 CFM Front-to-Rear
      Heat Rejection to Ambient 107,000 BTU/hr (maximum)
      Electrical Service 440/480 VAC, 60 Hz, 3 phase, 50 amp service
      Physical Parameters 66" H x 38" W x 62" D1,200 pounds dry weight
      Refrigeration system 10 Hp hermetically sealed compressor
      Controller PID type Controller
      Interfacing RS-232 serial interface
    • ACM-CHL-5205
    • Temperature Range + 0°C to +20°C
      Number of Channels 1
      Cooling Capacity 26 KW at +5°C
      Heating Capacity -
      Temperature Stability ± 0.5°C or better
      Fluid (HTF) Ethylene Glycol / Water
      Reservoir Volume 59 Gallons
      Pump: Flow at Pressure 30 GPM at 30 PSI
      Input Power 440/480VAC, 60 Hz, 3ph, 50 amp
      Configuration Indoor, Air cooled
    • ACM-CHL-5206
      Temperature Range -20°C to +80°C (Loop 1)
      +10°C to +80°C (Loop 2)
      Number of Channels 2
      Cooling Capacity 750 Watts at -20°C (Loop 1)
      2250 Watts at +20°C (Loop 2)
      Heating Capacity 2.2 KW each loop
      Temperature Stability ± 0.25°C or better
      Fluid (HTF) Deionized Water / Ethylene Glycol
      Reservoir Volume 4 Gallons
      Pump: Flow at Pressure 3 GPM at 50 PSI
      Input Power 208/230VAC, 60Hz, 3ph, 30 Amp
      Configuration Indoor, Air cooled
      Recirculating Supply/ Return Fittings 1/2" Stainless Steel FPT
      Condenser Air Flow 700 CFM, front to back
      Electrical Service 208/230 volt, 60 Hz, 3φ, 30 amp
      Physical Parameters 62"H x 22.5"W x 30"D, 550 lbs
    • ACM-CHL-5207
      Temperature Range +15°C to +35°C
      Number of Channels 2
      Cooling Capacity 885 Watts @ +28°C (Loop 1)
      1465 Watts @ +28°C (Loop 2)
      Heating Capacity 2 KW each Loop
      Temperature Stability ± 1.0 °C or better
      Re-circulating Fluid (HTF) 5 Gallons (Loop 1 Closed Loop)
      None (Loop 2 Open Loop)
      Reservoir Volume 59 Gallons
      Pump: Flow at Pressure 4 GPM at 30 PSI, 2 GPM at 60 PSI, each
      Input Power 208/230VAC, 60Hz, 3ph, 40 Amp
      Configuration Indoor, Air cooled
      Condenser Air Flow 1,800 CFM Front-to-Rear
      Heat Rejection to Ambient 24,000 BTU/hr, maximum
      Electrical Service 208/230 VAC, 60 Hz, 3 phase, 40 amp service
      Physical Parameters 54" H x 36" W x 48" D
  • Biotech
  • Aerospace
  • Automotive
  • Semiconductor
  • medical industries
  • plastic industries
  • printing industries
  • laser cutting industries

Corporate Catalog

Corporate Catalog

Corporate Videos

Corporate Video

Product Videos

Product Videos

Exhibition

Exhibitions

Product Gallery

Product Gallery

Certifications

ACMAS Certifications
  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Downloads
  • Videos
  • Gallery
  • Enquiry
  • Contact Us
  • Blog
  • XML Sitemap

ACMAS Technologies (P) Ltd. All Rights Reserved. Website Designing Delhi | Website Promotion Delhi: Softlogics