Test Chamber & Scientific Equipment Manufacturers

Beer Froth and Co2 Test Manufacturers Beer Froth and Co2 Test Bath

  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Testimonials
  • Enquiry
  • Contact
  • Telephone: +91 11 47619688
  • Fax: +91 11 47619788
  • Email: info[@]acmasindia.com
  • Test Chambers
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Ovens
  • Bath & Chillers
  • Incubators
Product Range
  • Test Chamber
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Oven
  • Bath & Chillers
  • Incubators
Our Clients
  • Clients of ACMAS
World Wide Presence
  • Worldwide Presence of ACMAS
Achievements
  • Achievements of ACMAS
Resources
  • Resources
Weiber Advance Control Systems
  • Advance Control Systems
beer froth and co2 test
  1. Home
  2. Bath & Chiller
  3. Bath
  4. Beer Froth & Co2 Test
  • Co2 Test Bath Manufacturers

BEER FROTH AND CO2 TEST

A number of parameters are measured by laboratory technicians to ensure that the quality of beer meets the satisfaction of the customer. Among these parameters is Beer Foam analysis due to carbon dioxide generated. This is now possible with WEIBER beer froth and co2 test bath. It is specifically designed for the brewery application to check the quality of the foam and carbonization. This method is also known as photometric determination of total carbohydrates in beer.

  • SPECIAL FEATURES
  • CONSTRUCTION DETAILS
  • TECHNICAL SPECIFICATIONS
  • APPLICATIONS
  • Fitted with test tubes with ground in glass stoppers
  • Spectral photometer (optional)
  • Easy filling form the top with hinged protective lid
  • Low liquid level protection with optical and audible alarm signal
  • RS232 interface for PC-connection (Optional)
  • Calibration And Protocol Documentation
  • Air cooled refrigeration unit
  • CFC free refrigerant
  • Microprocessor based temperature controller (HMI+PLC as an option)
  • beer Froth c02 Test Suppliers

  • Aesthetically Designed- Designed according to the standards and principles underlining industry’s aesthetic values.
  • Corrosion Resistant Interior and Exteriors- Corrosion resistant coatings like epoxy coatings are applied inside and outside the baths to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient – the baths uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving.
  • Sturdy Construction – the baths are built with robustness to withstand stress and strain, giving it long life and ability to perform in extreme stress environments.
  • USB ports (optional)
  • Real time data acquisition system (optional)

Our beer froth test bath are double walled convection heated units. Outer body of our re-circulating chiller is constructed out of thick PCRC steel sheet, duly pre-treated with primers for rust proofing and painted with air drying paint/stove enamel/powder coating. The inside chamber of the unit is made of heavy gauge stainless steel sheet of grade ss-304. The unit is provided with top opening cover, made of stainless steel with steel concentric rings.

  • HEATING
  • Indirect heating system is provided in our chiller, comprising of air heaters made of high grade Kanthal A-1wires of suitable wattage. The temperature is evenly distributed throughout the chamber through natural waterconvection mechanism, ensuring a very good temperature sensitivity.

  • COOLING UNIT
  • An energy efficient cooling unit is installed in our recirculatory chiller. We use ISI marked high end CFC free compressors of Kirloskar / Tecumseh make, conforming to latest international standards and guidelines.

    DETAILED DESCRIPTION ALONG WITH SALIENT FEATURES ARE AS UNDER FOR REFRIGERATION MACHINE

    CONDENSING UNIT

    (1) AIR-COOLED CONDENSOR

    Air-cooled condenser is internally grooved finned copper tubes used for high heat transfer area, which not only reduce power consumption, but also bring down the condensation faster. This unit is designed. & verdigris & reduces the resistance, saves energy consumption and ensure good heat exchange.

    (A.) COMPRESSOR:

    HERMETIC COMPRESSOR

    Single stage Reciprocating Compressor. Give the High Efficiency compared to sealed compressors, Less Power Consumption , Accessible for repairing, low noise level, Less Vibrations, Wide Voltage Range, Designed for Extremely High Ambient ,Full warranty etc.

    COOLING SYSTEM

    The compressor is mounted perfectly to ensure recommended level of sound and vibration.

    (B.) REFRIGERATION CONTROL

    (a).Low and High Pressure switch of RANCO/Danfoss

    Which ensures the compressor and refrigeration system when low pressure will occurs it trip off the compressor. This is the only operator friendly switch can easily reset.

    (b).Hand Shut off Valve

    Is the only Condensing Unit, which is equipped with it. This valve is used for pump down the total gas in to the condenser & receiver in the faulty condition.

    (c).Liquid Dryer of Danfoss make

    Which is equipped in the liquid line for ministration of moisture in the liquid. It will collect all the moisture in side the refrigeration line as well as gas.

    (d).Moisture Indicator of Danfoss make

    The sight glass area in the Moisture Indicator shows at a glance the condition of the refrigerant system. The moisture indicator element changes colour and indicate if the system is safely dry, or dangerously wet.

    (e). Solenoid Valve of Castle make

    In most refrigeration applications, in order to automatically control the flow of fluids in a system, it is necessary to be able to start or stop the flow in the refrigerant circuit. An electrically operated solenoid valve is usually used for this purpose. Its basic function is the same as a manually operated shutoff valve, but it can be positioned in remote locations, and may be conveniently controlled by simple electrical switches.

    (f). Oil Separator of Stainless Steel 304

    The oil separator intercepts the oil mixed with compressed gas and returns it into the crankcase of the compressor, thus assuring an efficient lubrication of its moving parts. Also, it improves the overall efficiency in the system.

    (g). Suction Accumulator

    Maximum Efficiency of the relief device (expansion valve) because it is supplied with sub cooled Liquid.

    (h). Liquid Receiver

    As per ASME Section VIII Division I for storage of refrigerant.

  • TEMPERATURE RANGE
  • Temperature range of our recirculatory chiller models is 0°C to 95°C.

  • TEMPERATURE SENSTIVITY
  • Temperature inside our chiller are controlled with a sensitivity of ± 0.5°C or better (With PID Controller).

  • FRONT PANEL
  • Front panel of our re-circulating chiller comprises of on/off switches heating and mains indicator lamps and temperature controller.

    Temperature range

    ℃

    -5~+80℃

    Temperature stability

    ℃

    ±0.05

    Heater wattages

    W

     3000

    Interior size

    mm

    400W×400D×380H

    Overall dimensions

    mm

    500W×500D×620H

    Auxiliaries

     

    Shelf stand, fitration valve

    Power

    AC220V±10%, 50Hz

    Automatic De-icing system

    Optional

    Timer (999 minutes of hours)

    Optional

    Serial Port (Printer)

    Optional

    Real Time Program

    Optional

    Printer Report Program

    Optional

    Outer construction

    PCRC

    inner construction

    SS 304

Customizable sizes are also available

  • Beer Industry

Corporate Catalog

Corporate Catalog

Corporate Videos

Corporate Video

Product Videos

Product Videos

Exhibition

Exhibitions

Product Gallery

Product Gallery

Certifications

ACMAS Certifications
  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Downloads
  • Videos
  • Gallery
  • Enquiry
  • Contact Us
  • Blog
  • XML Sitemap

ACMAS Technologies (P) Ltd. All Rights Reserved. Website Designing Delhi | Website Promotion Delhi: Softlogics