Test Chamber & Scientific Equipment Manufacturers

Air to Air Thermal Shock Test Chambers, Automotive Thermal Shock Test Chamber India, Two Zone Thermal Shock Chambers

  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Testimonials
  • Enquiry
  • Contact
  • Telephone: +91 11 47619688
  • Fax: +91 11 47619788
  • Email: info[@]acmasindia.com
  • Test Chambers
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Ovens
  • Bath & Chillers
  • Incubators
Product Range
  • Test Chamber
  • Clean Room Equipments
  • Cooling Equipments
  • Furnaces
  • Laboratory Equipments
  • Oven
  • Bath & Chillers
  • Incubators
Our Clients
  • Clients of ACMAS
World Wide Presence
  • Worldwide Presence of ACMAS
Achievements
  • Achievements of ACMAS
Resources
  • Resources
Weiber Advance Control Systems
  • Advance Control Systems
Thermal Shock Test Chamber Manufacturers
  1. Home
  2. Test Chamber
  3. Automotive Industries
  4. Air To Air-Thermal Shock Test Chamber 2 Zone

Two Zone Thermal Shock Test Chambers
  • Air To Air Thermal Shock Test Chamber

AIR TO AIR-THERMAL SHOCK TEST CHAMBER: 2 ZONE

WEIBER designs and manufactures Air to Air Thermal Shock Test Chambers, Two Zone Thermal Shock Test Chamber, Customised Automotive Thermal Shock Test Chambers with separately controlled temperature zones (2 zone and 3 zone), depending on configuration of the chamber chosen. In thermal shock testing alternating high and low temperatures are fed in the chamber. To observe the product characteristics and failure occurrences caused by different materials and their thermal expansion coefficients, thermal shock testing is subjected to the product.

WEIBER offers several configurations of Two Zone Thermal Shock Chambers capable of meeting a wide variety of testing needs:

2 Zone: Two Zone Thermal Shock Test Chamber has hot and cold zones that can be controlled independently. A single basket product carrier moves between the hot and cold zones, subjecting the product to dramatic changes in temperature.

  • STANDARDS:
  • SPECIAL FEATURES:
  • OPERATING PRINCIPLE:
  • CONSTRUCTION DETAILS:
  • TECHNICAL SPECIFICATIONS:
  • APPLICATIONS:
  • GB/T 2443.1-2001 Test A: Low temp. Test
  • GB/T 2443.2-2001 Test B: Low temp. Test
  • GB/T 2443.22-2002 Test N: Low temp. Test
  • GJB 150.3-1986 High Temp. Test
  • GJB 150.4-1986 Low temp. Test
  • Horizontal air flow design assures uniform results
  • Temperature recorder provides24 hour part temperature recording as the load travelsfrom zone to zone.
  • Smooth transfer of specimen
  • Three levels of overheat protection and 2 levels of overcooled protection
  • Microprocessor temperature/humidity programmer.
  • Computer communications, networking, data-logging software.
  • Colour touch panel.
  • colour touch panel air to air thermal shock test chamber 2 zone
  • HMI+PLC in one unit
  • Door open and Door close alarm system.
  • Inbuilt calibration system.
  • Separate Inbuilt printer for printing graphs(optional).
  • inbuilt printer air to air thermal shock test chamber 2 zone
  • Less use of Electrical and Mechanical Components on the Top and Bottom of Chamber - Provides easy maintenance of chamber, increases durability because of proper air circulation; cooling systems kept at bottom of the chamber to provide proper environment for compressor.
  • Fullopening Door with Silicone Gaskets and Hinged on Left Side - Allows ease of complete access to the chamber and opening of door with less force; durable silicon gasket reduces temperature loss.
  • Heated Vewing Window - Heated viewing window allows viewing fog generated and proper viewing of the test sample.
  • Circulation Fan with Variable Speed -
    • Electrical efficiency
      Variable speed motor saves money by reducing energy bills, as it consumes less electricity than conventional motor.
    • Cooling Efficiency
      Variable speed enables gaining air conditioning efficiency or SEER.
    • Air Quality
      Variable speed motor helps clean the air efficiently. When the fan is in constant operation (indicated by the "Fan" setting on thermostat), the motor continues to slowly circulate air, allowing filters to capture more contaminants.
    • Humidity Control
      Variable speed motor combined with a Thermostat allows controlling the amount of humidity.
    • Quieter Operation
      Variable speed blower motor are significantly quieter thanits single-speed counterpart.
  • Air Cooled Refrigerated System - Air cooled refrigeration system offer various benefits like
    • low fan power consumption
    • resistant to corrosion and freezing conditions
    • requires very low maintenance
    • Guaranteed long life operation
  • PCRC Sheet Body - Powder coated steel body assures corrosion resistant chamber and allows working of chamber at high temperature applications.
  • Digital Output – Target and Performance Output of the chamber operations are in digital format(digits) giving precise reading.
  • Pre - Attached Data Logger with Data Analysis Software - Primary benefits of using data loggers is to automatically collect data 24-hour basis.Graph and table format of results can be produced automatically by the data logging software.
  • Self - Calibration System - WEIBER incorporate a self-calibration system, in each chamber,that is completely automatic to prevent errors that could result from failure to calibrate. The system continuously monitors the environment, sensing changes that could affect analysis, and re-calibrates accordingly using a built-in long-life calibrator The process takes just a few seconds, without operator intervention or additional supplies, quickly optimizing system parameters for the current conditions.
  • Open and Close Updates Through Mobile Network - Mobile technology has the potential to make services more flexible and keep informed, information anywhere at any time from mobile device, and can set alert system to know whether or not the chamber is being used.
  • Reliable – Construction, performance mechanism, controls and information system integration makes the equipment reliable.
  • Precise Control of Environmental Parameters - The set/ programmable parameters of the chamber are precise or have less deviation from original value,thus ensuring correct measurement.
  • Micro - Processor Based Controller – Microprocessor based controller enablesprecise control of temperature, humidity, pressure and other values. Benefits:
    • Processing speed is high
    • Provides flexibility to alter the system by changing software.
    • Compact in size.
    • Operation and maintenance easier.
    • Maintain precise values
  • Aesthetically designed - Designed according to the standards and principles underlining industry’s aesthetic values.
  • Corrosion Resistant interior and exteriors - Corrosion resistant coatings like epoy coatings are applied inside and outside the chamber to prevent against degradation due to moisture, salt spray, oxidation or exposure to a variety of environmental or industrial chemicals/ corrosive agents.
  • Energy Efficient – WEIBER chamber uses less energy to provide the same level of performance, comfort and convenience, thus making it energy conserving chamber.
  • CFC - Free Cooling - The air cooled refrigerator use CFC (chlorofluorocarbon)-free refrigerants those are ozone friendly and eco-friendly.
  • Sturdy Construction - WEIBER chambers are built with robustness to withstand stress and strain, giving the chamber long life and ability to perform in extreme stress environments.
  • Low Maintenance - WEIBER systems benefit inretaining proper functionality over long period of time.
  • Light Weight: Compact and superior materials ensure the chamber be light weight

In case of air to air chamber the heated air and cooled air are used

2 zone: Sample is placed in the test chamber at higher temperature than test temperature, in high-temperature chamber and low-temperature chamber. When it comes to low temperaturetest, cold chamber door open, and low-temperature chamber works.

When converted into high-temperature test, cold chamber door is closed, hot chamberdoors are opened, and test chamber works.

Conversion of mechanical action (transferring from high temperature to low temperature or low temperature to high temperature) can be completed in less than 1second, and thetemperature can be quickly stabilized. During the whole test, test sample is in no need to be moved, and without any humanintervention.

WEIBER Thermal Shock test chambers are double walled convection heated and cooled units. Outer body of our environmental chambers are constructed out of thick PCRC, pre coated corrosion resistant GI sheet duly pre-treated with primers and rust proofing and painted with long lasting stove enamel or elegantly powder coated. The inner chamber is made of heavy gauge stainless steel sheet of SS-304 grade). The gap between the walls is filled high grade mineral glass wool, which ensures maximum thermal efficiency in our chambers.

The unit is provided with single door, with viewing window made of thick plexi glass/float glass, to view the specimens, without disturbing the temperature of the chamber. This door is provided with magnetic door closer. This door is provided with lock and key arrangement. The unit is mounted on a sturdy steel frame. The unit is provided with various customized shelves in various permutations and combinations to suit individual requirements. The triple walled back of our Thermal Shock test chambers are provided with two/Four/Six/Eight (size specific) air circulation fans for uniform maintenance of the temperature throughout the chamber.

HMI+ PLC IN ONE UNIT:

hmi plc together air to air thermal shock test chamber 2 zone

Weiber provides better automatic controls for the chamber by integrating HMI and PLC together. This special feature is compelling alternative to traditional methods and provides a simplified, reduced cost control system architecture.
It works by following operating steps:

  • Sensors measure the physical quantity like temperature and convert them to electrical signal
  • The actuation device acts upon that electrical signal
  • At HMI interface between operator and chamber occurs.
  • The machine operates with the logic design controls controlled by software.
  • This signal is sent to the chamber by logic control devices and the chamber operates.

Basic features of HMI+PLC:

  • Processor of 1.6 GHz: High clock speed processing PLC that enables speed up processing to the functions. With 1.6GHz processing speed, the PLC system is capable of multitasking, processing of large data volume, and high performance.
  • Audio Output Alarm: Audio alarm alertin case of failures in any of the component controlling functions.
  • 256 MB of RAM: PLC of 256Mega Byte memory for running programmes offers high memory space for installing of more programs
  • COM Port: Com port provided for attaching RS 235/RS 485 cable.

com port air to air thermal shock test chamber 2 zone
  • USB Ports: A USB port provided for transferring data through communication between HMI and PLC. Various peripherals can be connected via USB hub.
    various peripherals air to air thermal shock test chamber 2 zone
  • Coloured Touch Panel: We provide coloured touch panel screen available in 2 sizes -7 inches and 10inches, displaying all the control features, digital clock, sensor layouts, data and values, graphics and pictures, navigations etc.
  • RS232 or RS485 Interface: Serial interface provided to get connectivity with internet, mobile and other data transmission. Single device to device interface and a communication bus that is used to form simple networks of multiple devices are available through RS485 interface. RS485 interface supports transmission speed of 2400, 4800, 9600, 19200, 38400 bits per second.

    Through Ethernet communication module, AC Drives, temperature controller and other industrial automation products can be connected quickly.

  • Touch Screen Size of 7 Inches and 10 Inches: HMI screen available in 2 sizes- 7inches and 10inches, as per user’s requirement. Screen displays the control features, images, data values and other programs.
  • rs 485 interface air to air thermal shock test chamber 2 zone
  • Expandable Memory with a SD Card: SD card plugged in appropriate slot for more memory requirement that will be read and used as part of device; for long storage requirements SD card may be added and store data with expanded memory.
  • sd card air to air thermal shock test chamber 2 zone
  • High Resolution Brilliant TFT Displays, 64k Colours: HMI screen displays 64000 different colours with good resolution, allowing large number of distinguished colours, easy to establish and work with. It shows entire new 2D drawing technique, the screen resolution enhanced for more realistic images and more colourful and vivid displays.
  • tft display air to air thermal shock test chamber 2 zone
  • Software Supports All Six IEC 61131 Programming Languages: Software supports all the six programming languages under international standard IEC 61131: Function Block Diagram, Ladder Diagram, Structured Text, Sequential Function Chart, Instruction List, and Continuous Function Chart.
  • E-remote Control Software: E-remote enables viewing the monitor and same screen shown on HMI at the production site, and control the manufacturing process via Ethernet.
  • A set of Trouble Shooting Tools: 3 troubleshooting tools provided with in the software
  • Simulation- Imitation of a situation as real situation
  • Debugging- Finding and reducing number of defects.
  • Online changes- Like change of IP address can be made online. Manual to operate the programs on request.
  • Increased Numbers of On - Board I/O peripherals (10-50): Maximum number of 50 I/O peripherals provided on request, to attach input and output devices to the HMI and PLC. Increased number of input and output peripherals allows adding of devices like printers, recorders, etc.,as per the need.
  • ethernet air to air thermal shock test chamber 2 zone
  • Data Logging and Free Pprogramming Software: Attached data logger with input program software provided. Through data logging software, HMI and PLC collect datathrough sensors, analyse the data and save and output the results of the collection and analysis. Examples of the types of information a data logging system can collect include temperatures, sound frequencies, vibrations, times, light intensities, electrical currents, pressure and changes in states of matter.

CoDeSys (Controller Development System) software technology

software screenshot air to air thermal shock test chamber 2 zone

Heating:
Indirect heating system is provided in our units, comprising of air heaters made of high grade Kanthal A-1 wires of suitable wattage. The warm air is evenly distributed throughout the chamber through efficient motor fans ensuring very good temperature sensitivity.

Cooling:
An energy efficient cooling unit is installed in our photostabilitytest chambers to enable studies at lower room temperatures. We use high end CFC free compressors of Kirloskar/Tecumseh / Bitzer/ Denfos make, conforming to latest international standards and guidelines.

DETAILED DESCRIPTION ALONG WITH SALIENT FEATURES ARE AS UNDER FOR REFRIGERATION MACHINE

CONDENSING UNIT

AIR-COOLED CONDENSOR

Air-cooled condenser is internally grooved finned copper tubes used for high heat transfer area, which not only reduce power consumption, but also bring down the condensation faster. This unit is designed. &verdigris& reduces the resistance, saves energy consumption and ensure good heat exchange.

COMPRESSOR:

  • HERMETIC COMPRESSOR
    Single stage Reciprocating Compressor. Give the High Efficiency compared to sealed compressors, Less Power Consumption , Accessible for repairing, low noise level, Less Vibrations, Wide Voltage Range, Designed for Extremely High Ambient ,Full warranty etc
  • COOLING SYSTEM
    The compressor is mounted perfectly to ensure recommended level of sound and vibration.

REFRIGERATION CONTROL

  • Low and High Pressure switch of RANCO/Danfoss

    Which ensures the compressor and refrigeration system when low pressure will occurs it trip off the compressor. This is the only operator friendly switch can easily reset.

  • Hand Shut off Valve
    Is the only Condensing Unit, which is equipped with it. This valve is used for pump down the total gas in to the condenser & receiver in the faulty condition.
  • Liquid Dryer of Danfoss make
    Which is equipped in the liquid line for ministration of moisture in the liquid. It will collect all the moisture in side the refrigeration line as well as gas.
  • Moisture Indicator of Danfoss make
    The sight glass area in the Moisture Indicator shows at a glance the condition of the refrigerant system. The moisture indicator element changes colour and indicate if the system is safely dry, or dangerously wet.
  • Solenoid Valve of Castle make
    In most refrigeration applications, in order to automatically control the flow of fluids in a system, it is necessary to be able to start or stop the flow in the refrigerant circuit. An electrically operated solenoid valve is usually used for this purpose. Its basic function is the same as a manually operated shutoff valve, but it can be positioned in remote locations, and may be conveniently controlled by simple electrical switches.
  • Oil Separator of Stainless Steel 304

    The oil separator intercepts the oil mixed with compressed gas and returns it into the crankcase of the compressor, thus assuring an efficient lubrication of its moving parts. Also, it improves the overall efficiency in the system.

  • Suction Accumulator
    Maximum Efficiency of the relief device (expansion valve) because it is supplied with sub cooled Liquid.
  • Liquid Receiver
    As per ASME Section VIII Division I for storage of refrigerant.
  • Temperature Control: The temperature inside our temperature and humidity controltest chambers is controlled through Nano technology based HMI & PLC controller.
  • Temperature Range: Temperature range of our standard Chamber is -2°C to +40°C. . However we have the capacity to modify the same to suit the individual specialized requirements of our customers.
  • Temperature Sensitivity: Temperature inside our Temperature And Humidity Control test chambers are controlled with a sensitivity of + 0.3 o C or better.
  • Illumination: OurTemperature and Humidity Control test chambersare provided with door operated illumination system comprising of fluorescent lights, beside two panels of diffused fluorescent light panel located at the either side of the chamber to enable the user to conduct the photo periodic tests and experiments.
  • Insulation: The gap of 75 mm between the outer and the inner wall is filled with special grade glass wool to prevent thermal losses.
  • Mineral Glass Wool Insulation: Glass mineral wool is one of the most environmentally friendly, stable and sustainable insulates available. Glass wool is incombustible by nature. Euro class classification is A. It does not propagate flames and toxic smokes. Thanks to a dense entanglement of materials with a low conduction and trapping a great amount of air, glass wool is an excellent thermal insulant. The thickest it is, the best thermal resistance it has, thus reducing heat losses in our equipment’s for better sensitivity and economical operations. And its impact on the environment in manufacture, use and disposal is minimal.
  • Air Circulation: Triple walled back of unit is fitted with two air circulation fans for maintaining temperature uniformly throughout the chamber

Features of Coaxial Circulation Fan:

  • Vacuum impregnated stator winding with dr. back varnish under red baktol
  • Non-hygroscopic.
  • Best IR value
  • Bright bar (EN - 8 class) shaft.
  • Bush bearing of branded companies.
  • Surge comparison testing in fans and pumps eliminates into turn short circulating of the stator.
  • Pressure die-casted-rotor manufactured with zero error.
  • Boats of high accuracy

Doors: Triple walled back of unit is fitted with two air circulation fans for maintaining temperature uniformly throughout the chamber

Voltage: To work on 220/230V A.C. supply.

Port hole: port holes with silicon enclosure is provided at back side of the chamber. Through the port hole you can input sensors, wires and other test equipment. Silicone foam plugs have excellent temperature and humidity resistance and offer very good thermal insulation. Generally a single port hole is given but more numbers ca be increased according to customers request.

    Specification Air to Air
    Power Requirements 220/230V, 50/60Hz
    Electricity 1 phase or 3 phase as requested
    External Dimension (WXDXH) 1700mm x 2400mm x 2100mm (can be adjusted on request)
    Internal Dimension (WXDXH) 508mm x 508mm x 457mm (can be adjusted onrequest)
    Sample Basket (WXDXH) 482mm x 482mm x 25mm (can be adjusted onrequest)
    Temperature Range Hot zone:+60° C to +200° C
    Cold zone: -75° C to 0° C
    Temperature Fluctuation ±1°C
    Max. Load Current 50A
    Weight 680kg
    Noise 65dB or less
    Temperature Controller HMI+PLC
    Display LCD
    Safety thermostats
    Automatic temperature setting Yes
  • Test houses and research
  • Automotive industry
  • Electronics industry
  • Aviation and space industries
  • Laboratory equipment.

Corporate Catalog

Corporate Catalog

Corporate Videos

Corporate Video

Product Videos

Product Videos

Exhibition

Exhibitions

Product Gallery

Product Gallery

Certifications

ACMAS Certifications
  • Home
  • About Us
  • Services
  • Certifications
  • Clients
  • Downloads
  • Videos
  • Gallery
  • Enquiry
  • Contact Us
  • Blog
  • XML Sitemap

ACMAS Technologies (P) Ltd. All Rights Reserved. Website Designing Delhi | Website Promotion Delhi: Softlogics